Construction sites
Temporary supply configured to equipment loads, distribution arrangement and destination requirements.
Sockets & Temporary Power · Project Distribution
For temporary power distribution and circuit protection at construction, maintenance, temporary-work and event sites. Incoming supply, branch circuits, protection, sockets and metering are configured to loads and project requirements.
Choose empty enclosures or assembled equipment. Empty supply does not include electrical components, sockets or internal wiring by default. Inclusion of stands, cables, plugs, castors and other accessories must be specified in the supply list.

These uses help assess suitability; they are not completed project references.
Temporary supply configured to equipment loads, distribution arrangement and destination requirements.
Circuits defined by maintenance tools and equipment supply, socket and protection needs.
Distribution scheme confirmed against simultaneous use, installation location and mobility needs.
Temporary circuits planned around event equipment, supply interfaces and operating environment.
Options follow manual pages 26–27. Currents, sockets, protection, mounting and operating environment require a combined assessment. Compliance with every country’s construction rules, a fixed distribution hierarchy, protection-stage count or outdoor operating conditions is not assumed.
| Item | Listed options / configuration | To confirm for the project |
|---|---|---|
| Operating voltage | AC 220 / 230 / 380 / 400 V | Other voltages are project-specific. |
| Operating frequency | 50 / 60 Hz | Other frequencies are project-specific. |
| Distribution arrangement | Single-phase / three-phase | Phase arrangement, wiring and earthing system follow the project scheme. |
| Incoming & branch current | Project-specific | Determined by load capacity, simultaneous use and protection scheme. A socket current rating is not the box incoming current rating. |
| Circuits & sockets | Circuit count and sockets configured as required | Socket type, standard, quantity, rated current and voltage depend on the equipment and destination. |
| Degree of protection | IP44 / IP54 / IP55 | Confirm specific construction, installation and operating conditions; other ratings require assessment. |
| Enclosure steel thickness | 1.2 / 1.5 / 2.0 mm | Other thicknesses are project-specific; doors, mounting plates and other parts are confirmed separately. |
| Material & surface treatment | Cold-rolled steel / galvanized steel / stainless steel | Material by part, finish and colour follow project requirements. |
| Protection configuration | Short-circuit, overload and residual-current protection | Configured to distribution hierarchy, loads and project requirements; no fixed number of protection stages is assumed. |
| Installation | Wall-mounted / stand-mounted / floor-standing | Confirm installation conditions; mobility accessories are optional. |
| Dimensions & interfaces | Width × height × depth, in mm | Cable entry, socket interfaces and rain-protection construction follow the scheme; unrestricted outdoor suitability is not implied. |
Provide destination requirements and actual operating conditions to confirm the distribution arrangement, protection configuration and installation scheme.
Final parameters, configuration and scope of supply are subject to the confirmed drawings and order agreement.
Mechanical enclosure supply for subsequent assembly by the customer.
Enclosure with the agreed components and internal wiring.
The supply list must specify accessories and interfaces. The temporary-power designation does not imply that stands, cables, plugs or castors are included. Site installation and external wiring are subject to a separate order agreement.
Start with destination and intended use, then define circuits and supply scope from equipment loads, simultaneous use and site conditions.
Use Additional Requirements for destination, loads, sockets and operating environment. After preparing the draft, attach equipment lists, plug information and electrical drawings in your email app.
Request a Temporary Power QuoteIncoming, assembly and outgoing checks follow the confirmed product configuration and order scope.
Required documents, submission stages and any witness or special inspection requirements are agreed before the order.
No. Incoming and branch currents depend on equipment loads, simultaneous use and protection scheme. A socket rating describes that socket only.
No. Destination rules, distribution arrangement, protection and site conditions require project confirmation. No fixed hierarchy or number of protection stages is promised.
No. IP44/IP54/IP55 are options requiring project confirmation. Construction, mounting, rain protection and actual operating conditions must be assessed together.
Not by default. Empty supply does not include electrical components, sockets or wiring. Stands, cables, plugs, castors and other accessories must be itemized in the supply list.
The quote button preselects this product. Enter destination, load, socket and installation needs, prepare the draft, then attach information and review in your email app before sending.
Final parameters, configuration and scope of supply are subject to the confirmed drawings and order agreement.